2 * 4awg + 4awg triplex servicio de cable conductor de aluminio cable ABC
Puerto: | Qingdao guangzhou shanghai niongbo |
Términos de pago: | L/C,D/A,D/P,T/T,Western Union |
Capacidad de suministro: | 100 Kilómetro/s por Day |
Lugar del origen: | Henan China |
Marca: | Hongda |
Número de Modelo: | ABC blv |
Tipo: | Aislado |
Uso: | Gastos generales |
Material conductor: | ACSR AAC AAAC |
Tipo de conductor: | Trenzado |
Material aislante: | XLPE/PVC/PE/ |
Color: | Negro o según sus necesidades |
Aislamiento: | XLPE PE PVC |
Tensión de: | 450/750V300/500V300/300 V (600/1000 V |
Material: | ACSR AAC AAAC |
Embalaje: | En bobina/en tambor |
Tipo de embalaje: | En bobina o en tambor |
1 Operating Characteristics
Rated voltage: 0.6/1kV
Max. permissible continuous operating temperature of conductor with XLPE insulation: 90°C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250°C
The ambient temperature under installation should not be lower than: -20°C
The bending radius of cable is recommended as following:
When the diameter of cable is less than 25mm: not less than 4 times of the diameter of cable
When the diameter of cable is not less than 25mm: not less than 6 times of the diameter of cable
When the cable is used in alternative current system, the rated voltage of cable should be at least equal to the rated voltage of system; when the cable is used in direct current system, the rated voltage of system should not greater than 1.5 times of the rated voltage of the cable.
2. Application Properties
2.1.ABC cable is primarily used on lighting,outdoor lighting,and temporary service for construction.
2.2.The conductor longterm maximum working temperature: PE insulation should not exceed 75°C, XLPE insulation should not exceed 90°C.
2.3.During short circuit (maximum permanent time is not more than 5 seconds), the maximum temperature of cable conductor: XLPE insulation 250 °C, High-density polyethylene insulation 150°C.
2.4.When laying the cable,minimum ambient temperature of laying should not be lower than -20°C.
2.5.The minimum bending radius: ≥20 (D+d) ±5mm, D is the cable overall diameter, d is the conductor diameter.
3.ABC cable meets or exceeds the following specifications:
3.1. Aluminum cable,1350-H19 for electrical purposes.
3.2. Aluminum conductors,concentric-lay-stranded.
3.3.Aluminum conductors,concentric-lay-stranded,coated steel reinforced(ACSR).
3.4.Concentric-lay-stranded 6201-T81 conductors.
3.5.Compressed round stranded aluminum conductors using single input conductor.
ABC cable meets or exceeds all applicable requirements of ANSI /ICEA S-76-474.
Duplex Service Drop
1Application
Primarily used for 120volt overhead service application such as street lighting,outdoor lighting,and temporary service for construction.To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2Construction
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) |
Allo wable Amp acitles | ||||||
Size (A WG) |
Stranding | Insul Thick(Mils) |
Size (AWG) |
Stranding | Rated Strength (lbs.) |
inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 10.36 | 61 | 61 | 85 | 70 |
Collie | 6 | 7 | 45 | 6 | 7 | 563 | 10.36 | 64 | 64 | 85 | 70 |
Dachshund | 4 | 1 | 45 | 4 | 7 | 881 | 10.36 | 92 | 92 | 115 | 90 |
Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 10.36 | 96 | 96 | 115 | 90 |
Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 14.88 | 147 | 147 | 150 | 120 |
Malemute | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 14.88 | 234 | 234 | 205 | 160 |
Triplex Service Drop
1Application
Used to supply power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2Construction
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) |
Allo wable Amp acitles | ||||||
Size (A WG) |
Stranding | Insul Thick(Mils) |
Size (AWG) |
Stranding | Rated Strength (lbs.) |
inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Pateela | 6 | 7 | 45 | 6 | 7 | 563 | 14.88 | 103 | 103 | 85 | 70 |
Oyster | 4 | 7 | 45 | 4 | 7 | 881 | 14.88 | 154 | 154 | 115 | 90 |
Clam | 2 | 7 | 45 | 2 | 7 | 1350 | 20.58 | 233 | 233 | 150 | 120 |
Murex | 1/0 | 7 | 60 | 1/0 | 7 | 1990 | 20.58 | 374 | 374 | 205 | 160 |
Purpura | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 20.58 | 368 | 368 | 205 | 160 |
Nassa | 2/0 | 7 | 60 | 2/0 | 7 | 2510 | 25.42 | 462 | 462 | 235 | 185 |
Melita | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 29.97 | 562 | 562 | 275 | 215 |
Portunus | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 29.97 | 696 | 696 | 315 | 245 |
Nannynose | 336.4 | 19 | 60 | 336.4 | 19 | 6146 | 38.79 | 1118 | 1118 | 420 | 325 |
Quadruplex Service Drop
1Application
Used to supply 3-phase power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
2Construction
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length | Weight Per 1000 ft.(lbs.) |
Allo wable Amp acitles | ||||||
Size (A WG) |
Stranding | Insul Thick(Mils) |
Size (AWG) |
Stranding | Rated Strength (lbs.) |
inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Clydessdale | 4 | 1 | 45 | 4 | 7 | 881 | 20.58 | 198 | 198 | 100 | 80 |
Pinto | 4 | 7 | 45 | 4 | 7 | 881 | 20.58 | 211 | 211 | 100 | 80 |
Mustang | 2 | 7 | 45 | 2 | 7 | 1350 | 25.42 | 318 | 318 | 135 | 105 |
Criollo | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 25.42 | 503 | 503 | 180 | 140 |
Percheron | 2/0 | 11 | 60 | 2/0 | 7 | 2510 | 29.97 | 619 | 619 | 205 | 160 |
Hanovarian | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 35.18 | 764 | 764 | 235 | 185 |
Oldenburg | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 35.18 | 945 | 945 | 275 | 210 |
Lippizaner | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 38.79 | 1519 | 1519 | 370 | 280 |
Q1: Is your company a factory or trade company ?
A: We are factories, more than 20 years in China.
Q2: What's the quality assurance we can provide and how do we control quality?
A:100% inspection on assembly lines. All controls, inspections, equipment, fixtures, total production resources and skills are inspected to confirm they consistently achieve the required quality levels.
Q3: What's your payment terms?
A: We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated.
Trade assurance on Alibaba is also available.
Q4: What’s the delivery time?
A: Formal order needs 10–25 days.
Q5: Can I get some samples?
A: Yes, sample order is available for quality check and market test.
Q6: Do you have the products in stock?
A: Yes, we will keep some general ones in stock.
Q7; What is your MOQ?
A: It`s base on the cable type or wire type. We also accept Small order .
Q8; Where is your factory ?
A: we are in henan , middle of china .
ABC cable | electrical wire | power cable |
armored power cable | Concentric cable | control cable |