<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Building wire cable &#8211; JYTOP Cable</title>
	<atom:link href="https://spanish.baoliyy.com/tag/building-wire-cable/feed/" rel="self" type="application/rss+xml" />
	<link>https://spanish.baoliyy.com</link>
	<description>CONDUCTOR AAC / AAAC / ACSR, Cable XLPE, Cable PVC, Cable ABC, Cable de alimentación</description>
	<lastBuildDate>Thu, 05 Sep 2019 16:14:49 +0000</lastBuildDate>
	<language>es</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=5.2.29</generator>
	<item>
		<title>Building wire BV ZR-BV BVR BLV BVV BLVV BVVB cable 1.5mm  2.5mm</title>
		<link>https://spanish.baoliyy.com/building-wire-bv-zr-bv-bvr-blv-bvv-blvv-bvvb-cable-1-5mm-2-5mm/</link>
				<comments>https://spanish.baoliyy.com/building-wire-bv-zr-bv-bvr-blv-bvv-blvv-bvvb-cable-1-5mm-2-5mm/#respond</comments>
				<pubDate>Thu, 05 Sep 2019 16:14:49 +0000</pubDate>
		<dc:creator><![CDATA[admin]]></dc:creator>
				<category><![CDATA[zzhd]]></category>
		<category><![CDATA[Building wire cable]]></category>
		<category><![CDATA[BV wire cable]]></category>
		<category><![CDATA[cable 1.5mm 2.5mm]]></category>

		<guid isPermaLink="false">https://spanish.baoliyy.com/building-wire-bv-zr-bv-bvr-blv-bvv-blvv-bvvb-cable-1-5mm-2-5mm/</guid>
				<description><![CDATA[De construcci&#243;n alambre BV ZR-BV BVR BLV BVV BLVV BVVB cable 1,5mm 2,5mm &#160; &#160; Conductor tipo C&#243;digo Tensi&#243;n Nominal U0/U No de n&#250;cleos Rango de secci&#243;n transversal mm2 &#160; &#160; Cable aislante de PVC con n&#250;cleo de cobre&#160; BV 450/750 V 1 1,5-120 &#160; Cable ign&#237;fugo aislado de PVC con n&#250;cleo de cobre ZR-BV [&#8230;]]]></description>
								<content:encoded><![CDATA[<div id="specifications">
<div class="user-content-scale">
<div class="user-content no-init super-text-description">
<div class="specifications-wrap richtext richtext-detail rich-text-description">
<p>De construcci&oacute;n alambre BV ZR-BV BVR BLV BVV BLVV BVVB cable 1,5mm 2,5mm</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div style="overflow:auto"><table border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td rowspan="2">
<p align="center">Conductor tipo</p>
</td>
<td rowspan="2">
<p align="center">C&oacute;digo</p>
</td>
<td rowspan="2">
<p align="center">Tensi&oacute;n Nominal U<sub>0</sub>/U</p>
</td>
<td rowspan="2">
<p align="center">No de n&uacute;cleos</p>
</td>
<td rowspan="2">
<p align="center">Rango de secci&oacute;n transversal mm<sup>2</sup></p>
</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>&nbsp;</td>
</tr>
<tr>
<td>
<p align="center">Cable aislante de PVC con n&uacute;cleo de cobre<strong>&nbsp;</strong></p>
</td>
<td>
<p align="center">BV</p>
</td>
<td>
<p align="center">450/750 V</p>
</td>
<td>
<p align="center">1</p>
</td>
<td>
<p align="center">1,5-120</p>
</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>
<p align="center">Cable ign&iacute;fugo aislado de PVC con n&uacute;cleo de cobre</p>
</td>
<td>
<p align="center">ZR-BV</p>
</td>
<td>
<p align="center">450/750 V</p>
</td>
<td>
<p align="center">1</p>
</td>
<td>
<p align="center">1,5-120</p>
</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>
<p align="center">Alambre aislado de PVC con n&uacute;cleo de aluminio</p>
</td>
<td>
<p align="center">BLV</p>
</td>
<td>
<p align="center">450/750 V</p>
</td>
<td>
<p align="center">1</p>
</td>
<td>
<p align="center">2,5-120</p>
</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>
<p align="center">Cable flexible aislado PVC n&uacute;cleo de cobre</p>
</td>
<td>
<p align="center">BVR</p>
</td>
<td>
<p align="center">450/750 V</p>
</td>
<td>
<p align="center">1</p>
</td>
<td>
<p align="center">2,5-70</p>
</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>
<p align="center">N&uacute;cleo de cobre PVC aislado y enfundado alambre redondo</p>
</td>
<td>
<p align="center">BVV</p>
</td>
<td>
<p align="center">300/500 V</p>
</td>
<td>
<p align="center">1-5</p>
</td>
<td>
<p align="center">0,75-35</p>
</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>
<p align="center">N&uacute;cleo de aluminio PVC aislado y enfundado alambre redondo</p>
</td>
<td>
<p align="center">BLVV</p>
</td>
<td>
<p align="center">300/500 V</p>
</td>
<td>
<p align="center">1-5</p>
</td>
<td>
<p align="center">2,5-10</p>
</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>
<p align="center">N&uacute;cleo de cobre PVC aislado y enfundado alambre plano</p>
</td>
<td>
<p align="center">BVVB</p>
</td>
<td>
<p align="center">300/500 V</p>
</td>
<td>
<p align="center">2-3</p>
</td>
<td>
<p align="center">0,75-10</p>
</td>
<td>&nbsp;</td>
</tr>
<tr>
<td>
<p align="center">N&uacute;cleo de aluminio PVC aislado y enfundado alambre plano</p>
</td>
<td>
<p align="center">BLVVB</p>
</td>
<td>
<p align="center">300/500 V</p>
</td>
<td>
<p align="center">2-3</p>
</td>
<td>
<p align="center">2,5-10</p>
</td>
</tr>
</tbody>
</table></div>
<p><strong>Se recomienda la aplicaci&oacute;n de</strong></p>
<p>Uso en instalaciones el&eacute;ctricas, cableado fijo o conexiones flexibles para aparatos el&eacute;ctricos</p>
<div style="overflow:auto"><table border="1" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td rowspan="2">
<p align="center">Nominal</p>
<p align="center">Secci&oacute;n</p>
</td>
<td>
<p align="center">Conductor core</p>
</td>
<td rowspan="2">
<p align="center">Espesor de aislamiento</p>
</td>
<td colspan="2">
<p align="center">Medio de di&aacute;metro exterior</p>
<p align="center">&nbsp;</p>
</td>
<td colspan="2">
<p align="center">Resistencia del Conductor a 20 &deg;C m&aacute;x.</p>
<p align="center">&nbsp;</p>
</td>
<td rowspan="2">
<p align="center">Resistencia al aislamiento a 70 &deg;C m&aacute;x.</p>
<p align="center">&nbsp;</p>
</td>
</tr>
<tr>
<td>
<p align="center">N. &deg; de cables/di&aacute;metro individuales</p>
</td>
<td>
<p align="center">Min</p>
</td>
<td>
<p align="center">&iexcl;Max!</p>
</td>
<td>
<p align="center">Cu</p>
</td>
<td>
<p align="center">Al</p>
</td>
</tr>
<tr>
<td>
<p align="center">Mm<sup>2</sup></p>
</td>
<td>
<p align="center">Mm</p>
</td>
<td>
<p align="center">Mm</p>
</td>
<td>
<p align="center">Mm</p>
</td>
<td>
<p align="center">Mm</p>
</td>
<td>
<p align="center">&omega;/km</p>
</td>
<td>
<p align="center">&omega;/km</p>
</td>
<td>
<p align="center">&le;M&Omega; &bull; km</p>
</td>
</tr>
<tr>
<td colspan="8">
<p><strong>BV/ZR-BV/BLV/BVV/BLVV/BVVB/cable</strong></p>
</td>
</tr>
<tr>
<td>
<p align="center">1,5</p>
</td>
<td>
<p align="center">1/1 38</p>
</td>
<td>
<p align="center">0,7</p>
</td>
<td>
<p align="center">2,6</p>
</td>
<td>
<p align="center">3,2</p>
</td>
<td>
<p align="center">12,1</p>
</td>
<td>
<p align="center">/</p>
</td>
<td>
<p align="center">0.011</p>
</td>
</tr>
<tr>
<td>
<p align="center">2,5</p>
</td>
<td>
<p align="center">1/1 78</p>
</td>
<td>
<p align="center">0,8</p>
</td>
<td>
<p align="center">3,2</p>
</td>
<td>
<p align="center">3,9</p>
</td>
<td>
<p align="center">7,41</p>
</td>
<td>
<p align="center">11,8</p>
</td>
<td>
<p align="center">0.010</p>
</td>
</tr>
<tr>
<td>
<p align="center">4</p>
</td>
<td>
<p align="center">1/2 25</p>
</td>
<td>
<p align="center">0,8</p>
</td>
<td>
<p align="center">3,6</p>
</td>
<td>
<p align="center">4,4</p>
</td>
<td>
<p align="center">4,61</p>
</td>
<td>
<p align="center">7,39</p>
</td>
<td>
<p align="center">0,0085</p>
</td>
</tr>
<tr>
<td>
<p align="center">6</p>
</td>
<td>
<p align="center">1/2 76</p>
</td>
<td>
<p align="center">0,8</p>
</td>
<td>
<p align="center">4,1</p>
</td>
<td>
<p align="center">5,0</p>
</td>
<td>
<p align="center">3,08</p>
</td>
<td>
<p align="center">4,91</p>
</td>
<td>
<p align="center">0,0070</p>
</td>
</tr>
<tr>
<td>
<p align="center">10</p>
</td>
<td>
<p align="center">7/1 35</p>
</td>
<td>
<p align="center">1</p>
</td>
<td>
<p align="center">5,6</p>
</td>
<td>
<p align="center">6,7</p>
</td>
<td>
<p align="center">1,83</p>
</td>
<td>
<p align="center">3,08</p>
</td>
<td>
<p align="center">0,0065</p>
</td>
</tr>
<tr>
<td>
<p align="center">16</p>
</td>
<td>
<p align="center">7/1 70</p>
</td>
<td>
<p align="center">1</p>
</td>
<td>
<p align="center">6,4</p>
</td>
<td>
<p align="center">7,8</p>
</td>
<td>
<p align="center">1,15</p>
</td>
<td>
<p align="center">1,91</p>
</td>
<td>
<p align="center">0,0050</p>
</td>
</tr>
<tr>
<td>
<p align="center">25</p>
</td>
<td>
<p align="center">7/2 14</p>
</td>
<td>
<p align="center">1,2</p>
</td>
<td>
<p align="center">8,1</p>
</td>
<td>
<p align="center">9,7</p>
</td>
<td>
<p align="center">0.727</p>
</td>
<td>
<p align="center">1,20</p>
</td>
<td>
<p align="center">0,0050</p>
</td>
</tr>
<tr>
<td>
<p align="center">35</p>
</td>
<td>
<p align="center">7/2 52</p>
</td>
<td>
<p align="center">1,2</p>
</td>
<td>
<p align="center">9,0</p>
</td>
<td>
<p align="center">10,9</p>
</td>
<td>
<p align="center">0.524</p>
</td>
<td>
<p align="center">0.868</p>
</td>
<td>
<p align="center">0,0043</p>
</td>
</tr>
<tr>
<td>
<p align="center">50</p>
</td>
<td>
<p align="center">19/1 78</p>
</td>
<td>
<p align="center">1,4</p>
</td>
<td>
<p align="center">10,6</p>
</td>
<td>
<p align="center">12,8</p>
</td>
<td>
<p align="center">0.387</p>
</td>
<td>
<p align="center">0.641</p>
</td>
<td>
<p align="center">0,0043</p>
</td>
</tr>
<tr>
<td>
<p align="center">70</p>
</td>
<td>
<p align="center">19/2 14</p>
</td>
<td>
<p align="center">1,4</p>
</td>
<td>
<p align="center">12,1</p>
</td>
<td>
<p align="center">14,6</p>
</td>
<td>
<p align="center">0.268</p>
</td>
<td>
<p align="center">0.443</p>
</td>
<td>
<p align="center">0,0035</p>
</td>
</tr>
<tr>
<td>
<p align="center">95</p>
</td>
<td>
<p align="center">19/2 52</p>
</td>
<td>
<p align="center">1,6</p>
</td>
<td>
<p align="center">14,1</p>
</td>
<td>
<p align="center">17,1</p>
</td>
<td>
<p align="center">0.193</p>
</td>
<td>
<p align="center">0.320</p>
</td>
<td>
<p align="center">0,0035</p>
</td>
</tr>
<tr>
<td>
<p align="center">120</p>
</td>
<td>
<p align="center">37/2 03</p>
</td>
<td>
<p align="center">1,6</p>
</td>
<td>
<p align="center">15,6</p>
</td>
<td>
<p align="center">18,8</p>
</td>
<td>
<p align="center">0.153</p>
</td>
<td>
<p align="center">0.253</p>
</td>
<td>
<p align="center">0,0032</p>
</td>
</tr>
</tbody>
</table></div>
<p>&nbsp;</p>
<p>&nbsp;</p>
<div id="ali-anchor-AliPostDhMb-4a0bd" style="padding-top: 8.0px">
<div id="ali-title-AliPostDhMb-4a0bd" style="padding: 8.0px 0;border-bottom: 1.0px solid #dddddd"><span style="background-color: #dddddd;color: #333333;font-weight: bold;padding: 8.0px 10.0px;line-height: 12.0px">P&oacute;ngase en contacto con nosotros</span></div>
<div style="padding: 10.0px 0">
<h3 style="font-weight: bold;line-height: 20.0px;font-size: 1.17em;margin: 0.0px;font-family: arial;font-style: normal;background-color: #ffffff;padding: 0.0px;border: 0.0px;vertical-align: baseline;color: #333333"><span style="line-height: 36.0px;color: #a34b10;font-family: times new roman , times;font-size: 24.0px;background-color: #f5d0ff">M&aacute;s informaci&oacute;n y otras consultas por cable, p&oacute;ngase en contacto con nosotros de la siguiente manera:</span></h3>
<p style="margin: 0.0px;padding: 0.0px;color: #000000;font-family: arial;font-size: 12.0px;font-style: normal;font-weight: normal;background-color: #f5f5f5"><strong><span style="line-height: 18.0px;font-family: times new roman , times;color: #0000ff"><em><span style="line-height: 24.0px;font-size: 16.0px">HENEN HONGDA CABLE Co., LTD</span></em></span></strong><br /><span style="line-height: 18.0px;font-family: times new roman , times;color: #3366ff"><em><span style="line-height: 24.0px;font-size: 16.0px">Oficina: 21/F Yaxing Times Square Songshan camino Erqi zona Zhengzhou 450000 China</span></em></span><br /><span style="line-height: 18.0px;font-family: times new roman , times;color: #3366ff"><em><span style="line-height: 24.0px;font-size: 16.0px">F&aacute;brica: Huijin Rd y Changping Rd este desarrollo zona Zhandian&#8230; Jiaozuo 454950 China</span></em></span><br /><span style="line-height: 18.0px;font-family: times new roman , times;color: #3366ff"><em><span style="line-height: 24.0px;font-size: 16.0px">Tel: + 86 371 de 6097, 5619 | Fax: + 86 371, 6097, 5616</span></em></span><br /><span style="line-height: 18.0px;font-family: times new roman , times;color: #3366ff"><em><span style="line-height: 24.0px;font-size: 16.0px">Correo electr&oacute;nico: amy hongdacable @ yahoo.com</span></em></span><br /><span style="line-height: 18.0px;font-family: times new roman , times;color: #3366ff"><em><span style="line-height: 24.0px;font-size: 16.0px">M&oacute;vil: + 86 137834516132 (WhatsApp/Wechat)</span></em></span></p>
<p style="margin: 0.0px;padding: 0.0px;color: #000000;font-family: arial;font-size: 12.0px;font-style: normal;font-weight: normal;background-color: #f5f5f5">&nbsp;&nbsp;</p>
</div>
</div>
</div>
</div>
</div>
</div>
]]></content:encoded>
							<wfw:commentRss>https://spanish.baoliyy.com/building-wire-bv-zr-bv-bvr-blv-bvv-blvv-bvvb-cable-1-5mm-2-5mm/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
							</item>
	</channel>
</rss>
